A SINGLE STAGE HIGH POWER FACTOR AC/DC CONVERTER

Nowadays the ac/dc converters are widely used in many off-line power supplies. The increasing amount urges researchers to develop more efficient, smaller size, and low cost ac/dc converters. Traditionally, an ac/dc converter consists of a diode-bridge rectifier followed by a bulky capacitor and a high-frequency dc/dc converter. This kind of converter inevitably introduces highly distorted input current, resulting in a large amount of harmonics and a low power factor. paper proposes a single-stage high-power-factor ac/dc converter with symmetrical topology. The circuit topology is derived from the integration of two buck-boost power-factor-correction (PFC) converters and a full-bridge series-resonant dc/dc converter. Switch-utilization factor is improved by using two active switches to serve in the PFC circuits. A high power factor at the input line is assured by operating the buck-boost converters at discontinuous conduction mode. With symmetrical operation and elaborately designed circuit parameters, zero-voltage-switching on all the active power switches of the converter can be retained to achieve high circuit efficiency. The operation modes and design equations for the circuit parameters are proposed.

Friday, 27 May 2011

Simple Alarm System

The circuit presented here is a very simple and yet highly effective alarm system for protecting an object. The circuit requires no special devices and can be built using components that you will no doubt be able to find in the junk box. The alarm-triggering element is a simple reed switch. To generate the alarm signal itself any optical or acoustic device that operates on 12 V can be used: for example a revolving light, a siren, or even both. In the quiescent state the reed switch is closed. As soon as the reed switch opens, the input to IC1.B will go low (previously the potential divider formed by R2 and R3 held the input at 5.17 V, a logic high level).

Simple Alarm System circuit schematic

A turn-on delay of between 0 and approximately 90 s can be set using P1, and a turn-off delay of between 0 and approximately 20 s can be set using P2. When the system is turned on (using S1), the turn-on delay is activated, giving the user of the system at most 90 s to leave the object alone before the system goes into the armed state, and the object is then protected. Once the reed switch opens the turn-off delay of at most 20 s starts: this allows the rightful owner of the object to turn the system off before the alarm is triggered. If some unauthorised person causes the reed switch to open, the alarm will be triggered after the turn-off delay.

Simple Alarm System circuit schematic

Also, even if the reed switch is briefly opened and then closed again, the alarm will still be triggered. Once the alarm is triggered, T3 will conduct for about 45 s (because of R8 and C5). The turning off of the alarm is necessary to avoid the nuisance caused by a permanently sounding alarm system. The system then returns to the armed state, which means that the next time the reed switch is opened the alarm will trigger again. If it is not desired that the duration of the alarm be limited, for example if a visual indication is used, D5 should not be ?tted. The system can be extended by ?tting multiple reed switches in series. As soon as any one is opened, the alarm is triggered.

Simple Alarm System circuit schematic

When S1 is closed C3 charges via P1. Depending on the potentiometer setting, it takes between 0 and 90 s to reach the input threshold voltage of IC1.A. The output of IC1.A then goes low and D3 stops conducting. Assuming the reed switch is closed, the inputs of IC1.B stay high and the output therefore low. If the reed switch is opened after the turn-on delay expires the output of the gate will change state and turn on T1. This ensures that the output of the gate remains high even after the reed switch is closed again. C4 now starts charging via P2, reaching the input threshold voltage of IC1.C after between 0 and 20 s, again according to the potentiometer setting. The output of IC1.C goes low, and T2 and T3 are turned on – and the siren sounds.

Any Darlington transistor can be used for T3. At the same time, C5 charges via R8, reaching the input threshold of IC1.D in about 45 s. When the output of IC1.D swings low, it pulls the inputs of IC1.A low via diode D5: the siren stops and the system returns to the armed state. If the potentiometers P1 and P2 are replaced by ?xed resistors it is possible to build the circuit small enough to ?t in a match-box, without the need to resort to SMD components. This is ideal if the circuit is to be used to protect a motorbike. If the alarm system is to be used in a car, an existing door switch contact can be used instead of the reed switch. In this case an RC combination needs to be added to prevent false triggering. Use a 10 µF/25 V electrolytic for C6, a 100 k? resistor for R9 and a 1N4001 for D7. It is again possible to wire multiple door switch contacts in parallel: as soon as one contact closes, IC1.B will be triggered.